63 standardsHUD’s checklist of May 8, 2026

Every item on HUD’s NSPIRE inspection checklist for Section 8 units, on your phone.

UnitTuneUp covers every item on HUD’s NSPIRE checklist for Housing Choice Voucher units, with HUD’s severity and correction window for each.

Walk the unit room by room, photograph what you find, work through the fix list, check again, and keep a record. Find it before the inspector does. It runs in your browser and keeps your work on your device.

Open the app How it works

  • Life-threatening first
  • Photos and notes
  • Stays on your device

Let’s walk your unit, room by room.

Coverage

The whole HUD checklist

  • All 63 standards. Every standard and every deficiency on HUD’s NSPIRE checklist for Housing Choice Voucher units, the version dated May 8, 2026, in HUD’s own words.

  • HUD’s severity for each item. Life-threatening, severe, moderate or low, as HUD rates it.

  • HUD’s correction window for each item. 24 hours for life-threatening, 30 days for severe and moderate, and none for low.

  • The version on every report. Both reports name the checklist version and its HUD date, so anyone who reads one knows what the unit was checked against.

A tidy living room with a smoke alarm on the ceiling.

How it works

How to pre-check a Section 8 unit

  1. Add the unit. Enter the address, bedrooms, bathrooms, and whether there are fuel-burning appliances. The app builds the room list from that.

  2. Walk it room by room. Life-threatening items come first, for the whole unit. Then each room shows only the standards that apply to it. Tap Pass, Deficiency or Not applicable.

  3. Photograph and list the fixes. For each problem, pick the matching HUD deficiency, take a photo and add a note. The fix list sorts open items by due date and shows the severity and correction window HUD uses for each.

  4. Re-check and keep the record. Walk the open items again, take a proof photo and mark each one fixed. The app keeps the history: what was found, when, and how it was closed.

Early release

What you get today

UnitTuneUp is in early release. What works now, and what does not yet:

  • The whole walk: the life-threatening sweep, then every room, with the checklist on your phone.
  • One photo and a note per problem, with HUD’s severity shown for it.
  • A fix list with due dates, and a re-check pass with proof photos.
  • Watermarked on-screen previews of two reports: one for you, and an “Owner pre-check record” to show your housing authority.
  • Your work stays on your device, in your browser, until you choose to sign in. Signed in, it also syncs to our server, so you can get it back on another device.
  • Not yet, but coming: downloads and paid reports.

The checklist is still under review: built from HUD’s NSPIRE checklist for voucher units, its life-threatening items have not yet been checked line by line against the NSPIRE standards. The app says so on every walk screen.

See it in use

See the walk, and find what fails before February 1, 2027.

Three short clips of the walk, beside a clock on the latest date your housing authority can move Section 8 inspections to NSPIRE, HUD’s newer inspection standards.

Room by room, on your phone

The life-threatening sweep comes first, for the whole unit. Then each room shows only the standards that apply to it, and every deficiency you mark lands on the fix list with HUD’s severity and correction window.

Clip coming soon

The app in use: a living room walk with Smoke Alarm marked Pass.

Section 8 inspection checklist guide

Which outlet fails, and which passes

Within 6 feet of a sink, bathtub, shower, faucet or toilet in the same room, NSPIRE wants GFCI protection, and the inspector presses the test button. An outlet near water with no working GFCI is severe: the unit fails, with 30 days to fix.

Severe30 days to fix

Clip coming soon

An old outlet beside the sink: the tester’s button does not trip it.

Pass

Clip coming soon

A new GFCI outlet at the vanity, with its indicator lit.

GFCI and outlet guide

The TPR valve and its discharge line

The inspector checks the temperature pressure relief (TPR) valve and its discharge pipe by eye. A valve with an active leak or anything in its way, and a pipe that is damaged, capped, slopes upward or is of unsuitable material, are severe, with 30 days to fix.

Clip coming soon

A slow pan across a water heater: the TPR valve, and its discharge line running straight down.
  • SevereTPR valve leaking, or obstructed so it cannot be fully actuated
  • SevereDischarge pipe damaged, capped, sloping upward or of unsuitable material
  • ModerateDischarge pipe missing, or ending more than 6 inches or less than 2 inches from the flood level of its drain

Water heater guide

Guides

Guides for Section 8 landlords

All guides

FAQ

Questions landlords ask

Do I need an account?

No. Open the app and start. Sign in with your email and your work syncs to our server, so you can get it back on another device, or on a new one if this one is lost. Using an account is your choice.

Is my data uploaded?

Not unless you sign in. Everything you enter, photos included, stays in your browser’s own storage on your device. Sign in and it also syncs to our server, under your account, so you can get it back on another device. Not signed in, it lives only on this device: clear your browser data and it is gone.

What does it cost?

Nothing today. The walk, the fix list and the watermarked previews are free while UnitTuneUp is in early release. Paid downloadable reports come later, and you will see the price before you buy anything.

Find it before the inspector does.